Pinça Amperimétrica Digital DCM268N

Features

  • true RMS measurement of AC current and voltage
  • autorange for V - C - R
  • large 4000 count LCD display with bar graph
  • peak-hold function to record min. and max. readings for current and voltage
  • data-hold function
  • DCV (0.1mV~ 600V) and ACV (0.1mV~600V) measurements
  • ACA and DCA (0.01~1000A) current measurements
  • max. Ø for conductor: 30mm
  • resistance measurements: 0.1~40Mohm
  • frequency measurements: 0.001~4KHz
  • capacitance measurement: 0.001nF~40mF
  • temperature measurements: -40°C to 1,000°C
  • diode test, continuity test and backlight
  • K-type thermocouple measuring range: from -20°C to 1000°C
  • optional probes (not incl.): SONDE890, SONDE8264
  • safety: indoor use only (overvoltage Cat. III 600V)

Specifications

  • DC voltage: 0.4/4/40/400/600V
    • basic accuracy: ±(1.5% of rdg + 2 digits) / ±(0.8% of rdg + 2 digits) for 0.4V range / ±(2.0% of rdg + 2 digits) for 600V range
    • input impedance: 10Mohm
    • maximum input: 600V
  • AC voltage: 0.4/4/40/400/600V TRUE RMS
    • basic accuracy: ±(1.5% of rdg + 8 digits) / ±(1.0% of rdg + 10 digits) for 0.4V range / ±(2.0% of rdg + 8 digits) for 600V range
    • input impedance: 10Mohm
    • frequency range: 50-60Hz
    • maximum input: 600V
  • DC current: 40/400/1000V
    • basic accuracy: ±(2.8% of rdg + 10 digits) for 40A range / ±(2.8% of rdg + 8 digits) for 400A range / ±(3.0% of rdg + 8 digits) for 1000A range
    • overload protection: -
  • AC current: 40/400/1000A TRUE RMS
    • basic accuracy: ±(2.8% of rdg + 10 digits) for 40A range / ±(2.8% of rdg + 8 digits) for 400A range / ±(3.0% of rdg + 8 digits) for 1000A range
    • overload protection: -
  • resistance: 400/4K/40K/400K/4M/40M
    • basic accuracy: ±(1.0% of rdg + 4 digits) for 400ohm range / ±(1.5% of rdg + 2 digits) for 4K~400K range / ±(2.5% of rdg + 5 digits) for 4M range / ±(3.5% of rdg + 10 digits) for 40M range
    • overload protection: 15s max. 250V (all ranges)
  • capacitance: 4n/40n/400n/4µ/40µ/400µF/4mF/40mF
    • accuracy: ±(5.0% of rdg + 30 digits) for 4nF range / ±(5.0% of rdg + 20 digits) for 40nF range / ±(3.0% of rdg + 5 digits) for 400nF~40µF range / ±(4.0% of rdg + 10 digits) for 400µF range / ±(5.0% of rdg + 10 digits) for 4mF~40mF range
  • inductance: -
    • accuracy: -
  • frequency: 4,000KHz
    • basic accuracy: ±(1.5% of rdg + 2 digits)
    • overload protection: 15s max. 250V (all ranges)
  • temperature: -40°C~1,000°C
    • basic accuracy: ±(2.5% of rdg + 3°C)
  • overrange: yes "OL"
  • continuity buzzer: yes
  • transistor test: -
  • diode test: yes
  • low-battery indication: yes
  • maximum display: 3999
  • LCD display size: 22 x 35 mm
  • ranging mode: auto/manual
  • data hold: yes
  • backlight: yes
  • dimensions: 229 x 80 x 49mm
  • weight: ±303g
  • power supply: 1 x 9V battery (incl.)
  • packaging: blow mould case
  • accessories: manual / test leads / thermocouple / battery / carrying case
  • auto power-off: yes